Skip to main content

Table 6 Reported accuracy of 2D and 3D templating for TKA

From: A deep learning based automatic two-dimensional digital templating model for total knee arthroplasty

Author

Number of validation set

Method

Exact

Exact

Accurate

Accurate

Femur %

Tibia %

Femur %

Tibia %

Seaver et al. [10]

125

Manual 2D templating

56

61.6

97.6

95.2

Riechelmann et al. [7]

482

Manual 2D templating

55.2

52.9

96.5

94

Seaver et al. [10]

125

Automatic 2D templating

19.2

26.4

51.2

71.2

Pietrzak et al. [19]

31

Manual 3D templating (CT)

96.6

93.1

100

100

Marchand et al. [9]

239

Manual 3D templating (CT)

80

78

100

100

Klag et al. [1]

202

Automated 2D–3D pipeline

38

93.1

84

99.5

  1. 2D two-dimensional, 3D three-dimensional, CT computed tomography