Skip to main content

Table 2 Devices used for the osteotomy fixation and the type of material used for osteotomy gap filling

From: Double-level knee valgization osteotomy has high survivorship and a low complication rate in a single-center series of 58 cases with a mean clinical follow-up of 10 years

 

HTO (N = 58)

DFO (N = 58)

Side

Right

27 (46.6%)

27 (46.6%)

Left

31 (53.4%)

31 (53.4%)

Device

Tomofix LDFP (DePuy Synthes*)

 

54 (93.1%)

Tomofix MHT (DePuy Synthes*)

43 (74.1%)

 

Tomofix MHT-SS (DePuy Synthes*)

3 (5.2%)

 

Newclip ActivMotion (Newclip Technics**)

9 (15.5%)

3 (5.2%)

Arthrex PEEK Power Plate (Arthrex⁂)

1 (1.7%)

1 (1.7%)

Oatis C plate (S.B.M⁑⁑)

2 (3.4%)

 

Graft

Femoral head allograft

27 (46.7%)

 

Femoral head allograft + DFO wedge

2 (4%)

 

HydroxyColl® (RCSI )

1 (2%)

 

Precision Wedge ® (RTI Surgical‡‡)

5 (9%)

 

Quickset ® Bone Cement (Arthrex⁂) + 

Precision Wedge ® (RTI Surgical‡‡)

2 (4%)

 

Wedge from DFO

3 (5%)

 

No graft

18 (32%)

58 (100%)

  1. *DePuy Synthes, Oberdorf, Switzerland; **Newclip Technics, Nantes, France; ⁂Arthrex, Naples, Florida, USA; ⁑⁑ S.B.M, Lourdes, Hautes-Pyrénées, France; RCSI , Dublin 2, Ireland; ‡‡ RTI Surgical, Marquette, Michigan, USA