Skip to main content
  • Research article
  • Open access
  • Published:

Does the clinical and radiologic outcomes following total knee arthroplasty using a new design cobalt-chrome tibial plate or predecessor different?

Abstract

Background

This study aimed to compare clinical and radiographic outcomes for a new tibial component (Attune S +) and the previous design (Attune S) in total knee arthroplasty (TKA) patients using ATTUNE® posterior stabilized (PS) prosthesis and also assessed related factors for the development of tibial radiolucent line(RLL).

Methods

This retrospective study included 362 knees (179 Attune S, 183 Attune S +) with an average 4 years (range, 2–8) follow-up. Clinical outcomes, radiologic parameters and the incidence of RLL around the tibial component were compared through the serial assessment. For the subgroup analysis, radiologic parameters were compared between patients with and without RLL.

Results

There was no significant difference in terms of clinical outcomes and radiologic parameters between two designs. The incidence of RLL was not different through the serial follow-up (P > 0.05). In the subgroup analysis, the preoperative medial proximal tibial angle (83.7° versus 85.0°, P = 0.01) was smaller and preoperative hip-knee-ankle angle (169.1° versus 171.8°, P = 0.01) has more varus in the group with RLL than those without.

Conclusions

The clinical and radiologic outcomes including the incidence of tibial RLL between new design and predecessor were not significantly different at average 4 years follow-up. The development of tibial RLL was associated with preoperative varus deformity of tibia and lower limb alignment.

Introduction

Since John Insall and his colleagues first conceived the prototype of total knee arthroplasty in 1973, there have been various design changes in the artificial joint devices to achieve better surgical outcomes. However, implant loosening and long-term survival remain significant issues [1]. Recently, early failure of the tibial component has been reported in patients who received TKA using the initial design of ATTUNE® posterior stabilized (PS) prosthesis (Depuy Synthes, Warsaw, IN, USA) [2, 3]. RLLs often indicate the onset of bone weakening and loss of adhesion to cement, which can lead to the implant loosening [4]. Furthermore, the design of ATTUNE prosthesis showed higher incidence of radiolucent line (RLL) on postoperative radiographs compared with its predecessor (PFC, DePuy Synthes, Warsaw, IN, USA), which is closely related to stress shielding. This might be caused that the implant made of cobalt chrome (CoCr) alloy is more rigid than titanium alloy, and the tibial baseplate is thicker than that of other implants [5].

To address this concern, a new design of tibial plate (Attune S +) has been introduced, which has more cement pockets, increased surface roughness value, and reduced thickness of tibial baseplate [6]. In the previous of in vitro studies for the Attune S + , it was reported that the surface roughness of the tibial plate increased due to changes in the surface treatment, leading to an increase in pull-out strength [7]. Moreover, a recent comparative study reported that the new tibial baseplate was more advantageous in preventing medial proximal tibial resorption than the original baseplate [5]. However, there is still lack of evidence whether the clinical and radiologic outcomes including aseptic loosening of tibial component was significantly different between the two tibial designs with a mid-term follow-up.

Therefore, current study aims to compare the clinical and radiologic outcomes with a serial radiographic evaluation and its survival in patients with TKA using between the first and the second generation of Attune tibial plate. Moreover, we assessed related factors with the development of tibial RLL after the TKA. We hypothesized that the new Attune S + would have a lower incidence of RLL compared to the Attune S.

Materials and methods

Subjects

The current retrospective study included 694 knees that received TKA using the ATTUNE PS prostheses from March 2015 to December 2020. The inclusion criteria were primary TKA due to advanced primary osteoarthritis with varus malalignment. The exclusion criteria were knees with (1) stemmed prostheses, (2) conversion TKA after failed high tibial osteotomy, (3) experienced periprosthetic fracture before 2 years after surgery, or (4) a follow-up period less than 2 years (Fig. 1). They were divided into the predecessor design group (Attune S, n = 179) and the new design group (Attune S + , n = 183). Follow-up period was inevitably longer in the Attune S group (56.7 months ± 21.3 months) than in the Attune S + group (37 months ± 11.4 months) because Attune S + has been newly introduced in 2018 in our country. In addition, to assess the related factors with the development of tibial RLL, the groups with and without RLL were divided and compared the radiologic parameters as a subgroup analysis. Present study was approved by Institutional Review Board (BLINDED). Patient consent was waived due to retrospective nature of the study design.

Fig. 1
figure 1

Flowchart of patient recruitment. TKA total knee arthroplasty, HTO high tibial osteotomy

Surgical techniques

All TKAs were performed by a single senior surgeon (K.-I.K.). The mid vastus approach with tourniquet pressure with 220 mmHg was used. Femoral and tibial bone were resected with modified gap balancing technique [8]. Usually, the thickness of tibial cut at the lateral plateau was aimed to 9 mm. Bone resection was performed using intramedullary guide at distal femur and extramedullary guide at proximal tibia. If there was sclerotic surface at medial side after tibial bone resection, 2-mm diameter drill holes were made to enhance cement penetration on the sclerotic cutting surface [9]. Following bone preparation and balancing, pulsed lavage was performed to remove as much debris as possible prior to cementing the components. Just before applying the bone cement, all liquid and fine debris on the surface were thoroughly removed using suction and dry gauze. Cement was applied to both surface of bone cut and under surface of the tibial implant using a cement gun with pressurization. All components were implanted using high viscosity bone cement (SmartSet, DePuy Synthes, Warsaw, IN). At closure, a suction drain was inserted and maintained for 24 h in all patients. Isometric exercises were started shortly after return to ward. Initiation of assisted range of motion (ROM) exercises, and weight-bearing ambulation with crutches were initiated the day after the surgery.

Evaluation

The demographics including age, sex, body mass index (BMI), and follow-p period were compared between two groups. For clinical evaluation, ROM and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) [10] score were evaluated before and 2 years after surgery. Any complications were investigated until the last follow-up visit based on the standardized list, and the definitions of complications associated with TKA suggested by the Knee Society [11]. Anteroposterior (AP), lateral, full-length standing radiographs were taken at preoperative and postoperative 6 weeks, 6 months, 12 months, and then every follow-up year. A standardized protocol for radiographic evaluation was applied for all patients as the current study was performed in a single institute. Preoperative medial proximal tibial angle (MPTA), preoperative and postoperative hip-knee-ankle angle (HKAA) and the position of both components were evaluated using the Knee Society radiological evaluation method [12]. The RLL was defined as radiolucent intervals between the cement and either the implant or the bone [13]. It was regarded as being present when the bone adjacent to the radiolucency was sclerotic and parallel to the implant (Fig. 2) [13]. Since the radiographs should be taken horizontally with the tibial plate as much as possible, radiographs with a distance greater than 1.5 mm from the lowest part of the tibial plate to the line connecting the lower ends of the tibial plate were excluded as inadequately captured (Fig. 3) [14]. According to the Knee Society radiological evaluation method, the lower part of the tibial plate was divided into ten zones and the location of RLL was evaluated [12]. The incidence of RLL in ten zones below the tibial plate on standing AP and lateral radiographs taken 6 weeks, 6 months, 12 months, and then every follow up year after the surgery was compared between the attune S and attune S + groups. Medial proximal tibial angle (MPTA), preoperative and postoperative HKAA and postoperative position of components with α, β, γ, and Φ angles were compared at 6 weeks postoperatively. Measurements from these images were performed using a picture archiving and communication system (INFINITT, Seoul, Korea). To minimize observation bias, two independent investigators (M.K.U. and K.J.H.) performed the radiographic evaluations.

Fig. 2
figure 2

Serial anteroposterior radiographs of a 70-year-old female patient who underwent surgery using the Attune S +. Radiolucent line in cement–bone interface was visible at medial proximal tibia starting from the 6 months follow up after surgery. A, immediate postoperative; B, 6 weeks after surgery; C, 6 months after surgery; D, 1 year after surgery; E, 2 years after surgery

Fig. 3
figure 3

Trends of the incidence of radiolucent line between Attune S and Attune S + over time

To assess the related factors with the development of tibial RLL, the cohort was divided into two groups as a subgroup analysis: those with RLL and those without RLL during the entire follow-up period, regardless of the type of tibial implant used. The MPTA, preoperative and postoperative 6 weeks HKAA, and position of components (α, β, γ, and Φ) were compared between the two subgroups.

Data analyses

The incidence of RLL was compared using the Pearson chi-squared test. MPTA, preoperative and postoperative HKAA, α, β, γ, Φ angles, preoperative and postoperative ROM and WOMAC scores were compared between two groups (independent t-tests). Univariate and multivariate regression analysis was performed to determine the factors causing RLL after TKA. Statistical analyses were performed using SPSS version 25 (Chicago, IL, USA), and a P < 0.05 was considered statistically significant. The inter-observer reliabilities of measurement for radiological parameter such as position of components and HKAA was checked using the intraclass correlation coefficient and all values were greater than 0.8. Cohen’s kappa coefficient was evaluated to confirm the reliability of the incidence of the RLL and it was over 0.8 (Supplementary Table 1 and Table 2). Handling outliers or unexpected results were performed according to the decision-making tree based on the previous literature [15].

Post hoc power analyses using the significance set at an α of 0.05 were performed to determine whether the sample had sufficient power to detect significant differences. A power > 80% was considered sufficient, and all the significantly different variables met this criterion. Thus, it was determined that the present study was adequately powered.

Results

Clinical outcomes

There was no significant difference between Attune S and Attune S + groups in the demographics (Table 1). For the clinical outcomes, there were no significant differences in ROM and WOMAC scores (Table 2). Moreover, no implant failure or complications were observed in both groups until last follow-up.

Table 1 Patient demographics
Table 2 Preoperative and postoperative clinical score

Radiological outcomes

Regarding the radiologic outcomes, no significant differences were found between two groups in HKAA, MPTA, and postoperative position of components (α, β, γ, and Φ angles) (Table 3). The incidence of tibial RLL during 4 year serial follow-up was not significantly different between the groups reporting 10.0% (n = 18) and 8.2% (n = 15) in the Attune S and Attune S + groups, respectively (P = 0.54). Furthermore, all RLL were seen only in the AP zone 1 and were observed in the bone-cement interface. No case of RLL in the implant–cement interface was observed. Based on serial evaluations of radiographs, the incidence of RLL in AP zone 1 was not significantly different between the two groups at postoperative 6 weeks, 6 months, 1 year, 2 years, 3 years, and 4 years (P > 0.05) (Table 4) (Fig. 3).

Table 3 Radiologic evaluation between Attune S and Attune S +
Table 4 Incidence of radiolucent line (RLL) between attune S and attune S + according to the follow-up period

Subgroup analysis

Meanwhile, based on the subgroup analysis comparing the knees with and without RLL, the preoperative HKAA of the limb alignment was significantly smaller in the group with RLL (−169.1° ± 3.6°) than those without RLL (171.8° ± 5.9°) (P = 0.01) (Table 5). Moreover, preoperative MPTA was significantly smaller (more tibia vara) in the group with RLL (83.7° ± 2.0°) than the group without RLL (85.0° ± 2.7°) (P = 0.01). However, there was no significant difference in ROM, WOMAC score and the position of the tibial implant (α, β, γ, and Φ) between the two groups (P > 0.05) (Table 5). Multivariate regression analysis demonstrated that preoperative MPTA (B, −0.199; P = 0.035) and HKAA (B, −0.107; P = 0.030) were significant factors for the occurrence of RLL following TKA (Table 6).

Table 5 Comparison between groups with and without radiolucent line (RLL)
Table 6 Multivariate logistic regression analysis to determine factors for the occurrence of RLL

Multivariate regression analysis demonstrated that preoperative MPTA (B, −0.199; P = 0.035) and HKAA (B, −0.107; P = 0.030) were significant factors for the occurrence of RLL following TKA (Table 6).

Discussion

Contrary to our initial hypothesis, the main finding of the present study was that there was no significant difference in the clinical and radiologic outcomes including the incidence of tibial RLL on serial follow-up between the new design cobalt-chrome tibial plate and predecessor. Rather than the design of tibial plate, the incidence of RLL seems significantly associated with tibial shape (MPTA) and preoperative varus alignment.

It is widely cited that radiolucent lines (RLLs) greater than 2 mm and increasing in size at the bone–cement interface are indicative of loosening [9, 16]. In contrast, while definitive criteria for RLLs at the implant–cement interface in total knee arthroplasty (TKA) have not been clearly established, early debonding might be suggested and thus warrant close attention [17]. Attune S + was developed to address debonding between the tibial component and cement mantle, which was observed in the previous design (Attune S) and led to aseptic loosening [6]. Additionally, a previous study reported a higher incidence of RLL below the tibial component in Attune S compared to the its previous design, PFC Sigma (DePuy Synthes, Warsaw, IN) [2]. To enhance implant–cement interface bonding of Attune S, the new design features an enhanced rear surface roughness and additional cement pockets [6]. After the new design implant has been introduced, there were some studies that compared previous and new design. One study demonstrated that the medial proximal tibial bone resorption was significantly decreased in Attune S + compared with Attune S at 2 years follow-up [5]. Meanwhile, unlike our study, the study evaluated medial tibial bone resorption instead of RLL [5]. The authors attributed their findings to the reduced stress shielding caused by the addition of a cement pocket on the tibial component, which resulted in a thinner component in some areas [5]. However, previous studies investigated the different tibial designs and their association with bone resorption; however, the association is still controversial [18,19,20,21] and the thickness of the nonpocketed area remains the same [6]. On the other hand, a previous cadaveric study confirmed the effectiveness of these modifications, demonstrating a higher bond strength at the implant–cement interface in the new design compared with the previous one [22]. However, no significant differences were observed in the depth of cement penetration into the bone or the quality of the cement mantle [22]. Meanwhile, previous studies have established a significant association between the cement–bone interface and the incidence of RLL [23, 24]. In these studies, this association can be attributed to poor cement mantle quality on the bone or insufficient depth of cement penetration [23, 24]. Considering that the aforementioned cadaveric study found no difference in the depth of cement penetration or quality of the cement mantle between Attune S and S + , we can assume that there would be no difference in RLL occurrence at the cement–bone interface. This is consistent with our finding of no difference in tibial RLL occurrence between the two designs.

Based on the subgroup analysis to assess the related factors of RLL, the group with RLL had significantly smaller preoperative MPTA (more tibia vara) and larger varus angle of preoperative lower limb alignment than those without RLL. These results were consistent with previous studies that patients with larger varus angle of lower limb alignment before surgery are more likely to have increased RLL, especially AP 1 zone, or aseptic loosening after TKA [25, 26]. In those patients, the medial bone might be cut thinner or even none than usual if the lateral cut is planned 9–10-mm thickness, therefore it makes more difficult to expose the trabecular bone and more likely to encounter a sclerotic surface of medial proximal tibia. The sclerotic medial proximal tibia interferes with cement penetration and interdigitation of the cement [27]. A previous study also demonstrated that there was a significant association between tibial RLL and preoperative sclerosis of medial tibial bony surface [13]. As cement penetration plays an important role in the fixation of tibial implants after TKA, insufficient cement penetration to bony surface would be a major cause of loosening [27, 28]. To overcome this, we have applied thorough bony preparation with pulsatile lavage and meticulous cementing techniques such as multiple drilling on sclerotic bone, pressurization of the cement when applying to the bone, dry-cleaning tibia cut surface using suction or pulsed lavage, and cement application to both bony surface and implant, which has currently been introduced to ensure sufficient cement penetration and reduce the incidence of RLL and implant failure [23, 28, 29]. Although we have applied those improved cementing technique, TKA with severe tibia vara or severely varus knee showed higher incidence of tibial RLL compared with less severe cases. Nevertheless, using the technique, we could not find any tibial loosening cases regardless of development of RLL at zone 1. Therefore, thorough bony preparation and meticulous cementing technique would be important when patients with preoperative lager varus angle and smaller MPTA to avoid inadequate cement fixation resulting in RLL and potential implant failure.

The present study has several limitations. Firstly, it is a retrospective study, and although we confirmed that there was no significant difference in the patients’ age, gender, and BMI, bias may have been unaccounted for, and other biases may not have been fully excluded. Secondly, the study has a relatively small sample size and as Attune S + was only recently introduced, the group has a shorter follow-up period. Additionally, this was a single-center study design. To confirm this interesting finding about implant durability, larger-sample, multicenter prospective studies would be needed. Thirdly, although we tried to take radiological images under the same conditions as much as possible and made standards to evaluate the images, even slight differences in imaging, such as different rotation or tilting of the knees, could have affected the accuracy of the evaluation. Fourthly, due to loss to follow-up, serial radiologic evaluation cannot be achieved from all patients, which might be a confounding factor in the current study. Lastly, this study was conducted in an Asian cohort of patients with a lower body mass and women predominance when compared with those in Western cohorts with knee osteoarthritis, which may limit its generalizability.

Conclusion

The clinical and radiologic outcomes including the incidence of tibial RLL between a new design cobalt-chrome tibial plate or predecessor were not significantly different at an average of 4 years follow-up (10.0% versus 8.2%, P = 0.54). Meanwhile, the development of tibial RLL regardless of the design was associated with preoperative varus deformity of tibia and varus malalignment of lower limb. Our study emphasizes the clinical significance of preoperative varus deformity as a risk factor for RLL, suggesting that addressing this factor may be more critical than implant design choices.

Availability of data and materials

Data and materials are available when requested to corresponding author.

Abbreviations

TKA:

Total knee arthroplasty

PS:

Posterior stabilized

RLL:

Radiolucent line

MPTA:

Medial proximal tibial angle

HKAA:

Hip–knee–ankle angle

ROM:

Range of motion

WOMAC:

Western Ontario and McMaster Universities Osteoarthritis Index

AP:

Anteroposterior

References

  1. Saragaglia D, Rubens-Duval B, Gaillot J, Lateur G, Pailhe R (2019) Total knee arthroplasties from the origin to navigation: history, rationale, indications. Int Orthop 43:597–604

    Article  PubMed  Google Scholar 

  2. Bonutti PM, Khlopas A, Chughtai M, Cole C, Gwam CU, Harwin SF, Whited B, Omiyi DE, Drumm JE (2017) Unusually high rate of early failure of tibial component in attune total knee arthroplasty system at implant-cement interface. J Knee Surg 30:435–439

    Article  PubMed  Google Scholar 

  3. Staats K, Wannmacher T, Weihs V, Koller U, Kubista B, Windhager R (2019) Modern cemented total knee arthroplasty design shows a higher incidence of radiolucent lines compared to its predecessor. Knee Surg Sports Traumatol Arthrosc 27:1148–1155

    Article  PubMed  Google Scholar 

  4. Gallo J, Goodman SB, Konttinen YT, Wimmer MA, Holinka M (2013) Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms. Acta Biomater 9:8046–8058

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  5. Song SJ, Lee HW, Park CH (2023) Medial proximal tibial resorption after total knee arthroplasty according to the design of the cobalt chrome tibial baseplate. Arch Orthop Trauma Surg 143:3401–3407

    Article  PubMed  Google Scholar 

  6. DePuySynthes. Attune S+ technology: JRC; 2017.

  7. Maag C, Peckenpaugh E, Metcalfe A, Langhorn J, Heldreth M. 2020. Influence of alignment-specific physiological loading following intraoperative lipid/marrow infiltration and intraoperative motions upon tibial implant fixation. Orthopaedic Proceedings.

  8. Moro-oka TA, Shiraishi H, Iwamoto Y, Banks SA (2010) Modified gap-balancing technique in total knee arthroplasty: evaluation of the post-operative coronal laxity. Knee Surg Sports Traumatol Arthrosc 18:375–380

    Article  PubMed  Google Scholar 

  9. Cawley DT, Kelly N, McGarry JP, Shannon FJ (2013) Cementing techniques for the tibial component in primary total knee replacement. Bone Joint J. https://doiorg.publicaciones.saludcastillayleon.es/10.1302/0301-620X.95B3.29586

    Article  PubMed  Google Scholar 

  10. Giesinger JM, Hamilton DF, Jost B, Behrend H, Giesinger K (2015) WOMAC, EQ-5D and knee society score thresholds for treatment success after total knee arthroplasty. J Arthroplasty 30:2154–2158

    Article  PubMed  Google Scholar 

  11. Healy WL, Della Valle CJ, Iorio R, Berend KR, Cushner FD, Dalury DF, Lonner JH (2013) Complications of total knee arthroplasty: standardized list and definitions of the knee society. Clin Orthop Relat Res 471:215–220

    Article  PubMed  Google Scholar 

  12. Ewald FC (1989) The knee society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res. https://doiorg.publicaciones.saludcastillayleon.es/10.1097/00003086-198911000-00003

    Article  PubMed  Google Scholar 

  13. Smith S, Naima VS, Freeman MA (1999) The natural history of tibial radiolucent lines in a proximally cemented stemmed total knee arthroplasty. J Arthroplasty 14:3–8

    Article  PubMed  CAS  Google Scholar 

  14. Rizzo MG, Hall AT, Downing JT, Robinson RP (2021) High-viscosity versus a lower-viscosity cement penetration at dough phase in vivo in primary total knee arthroplasty. J Arthroplasty 36:1995–1999

    Article  PubMed  Google Scholar 

  15. Aguinis H, Gottfredson RK, Joo H (2013) Best-practice recommendations for defining, identifying, and handling outliers. Organ Res Methods 16:270–301

    Article  Google Scholar 

  16. Ecker ML, Lotke PA, Windsor RE, Cella JP (1987) Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines. Clin Orthop Relat Res 216:151–8

    Article  Google Scholar 

  17. Zhang Y, Putnam AW, Heiner AD, Callaghan JJ, Brown TD (2002) Reliability of detecting prosthesis/cement interface radiolucencies in total hip arthroplasty. J Orthop Res 20:683–687

    Article  PubMed  Google Scholar 

  18. Wong DW, Lee QJ, Lo CK, Wong YC, Law KW, Li AH (2020) Tibial tray thickness does not significantly increase medial tibial bone resorption: Using tibial bone density as an objective measurement method. Knee 27:572–579

    Article  PubMed  Google Scholar 

  19. Bendich I, Lawrie CM, Riegler V, Barrack RL, Nunley RM (2022) The impact of component design and fixation on stress shielding after modern total knee arthroplasty. J Arthroplasty 37:S221–S225

    Article  PubMed  Google Scholar 

  20. Tsukada S, Wakui M, Matsueda M (2013) Metal block augmentation for bone defects of the medial tibia during primary total knee arthroplasty. J Orthop Surg Res 8:36

    Article  PubMed  PubMed Central  Google Scholar 

  21. Yoon C, Chang MJ, Chang CB, Song MK, Shin JH, Kang SB (2018) Medial tibial periprosthetic bone resorption and its effect on clinical outcomes after total knee arthroplasty: cobalt-chromium vs titanium implants. J Arthroplasty 33:2835–2842

    Article  PubMed  Google Scholar 

  22. Jaeger S, Eissler M, Schwarze M, Schonhoff M, Kretzer JP, Bitsch RG (2022) Does tibial design modification improve implant stability for total knee arthroplasty? an experimental cadaver study. Bone Joint Res 11:229–238

    Article  PubMed  PubMed Central  Google Scholar 

  23. Ahn JH, Jeong SH, Lee SH (2015) The effect of multiple drilling on a sclerotic proximal tibia during total knee arthroplasty. Int Orthop 39:1077–1083

    Article  PubMed  Google Scholar 

  24. Wautier D, Ftaita S, Thienpont E (2020) Radiolucent lines around knee arthroplasty components : a narrative review. Acta Orthop Belg 86:82–94

    PubMed  Google Scholar 

  25. Li YR, Gao YH, Yang C, Ding L, Zhang X, Chen H, Liu J, Qi X (2019) Finite-element analysis of the proximal tibial sclerotic bone and different alignment in total knee arthroplasty. BMC Musculoskelet Disord 20:617

    Article  PubMed  PubMed Central  Google Scholar 

  26. Ritter MA, Davis KE, Davis P, Farris A, Malinzak RA, Berend ME, Meding JB (2013) Preoperative malalignment increases risk of failure after total knee arthroplasty. J Bone Joint Surg Am 95:126–131

    Article  PubMed  Google Scholar 

  27. Hampton CB, Berliner ZP, Nguyen JT, Mendez L, Smith SS, Joseph AD, Padgett DE, Rodriguez JA (2020) Aseptic loosening at the tibia in total knee arthroplasty: a function of cement mantle quality? J Arthroplasty 35:S190–S196

    Article  PubMed  Google Scholar 

  28. Ritter MA, Herbst SA, Keating EM, Faris PM (1994) Radiolucency at the bone-cement interface in total knee replacement. The effects of bone-surface preparation and cement technique. J Bone Joint Surg Am 76:60–5

    Article  PubMed  CAS  Google Scholar 

  29. Refsum AM, Nguyen UV, Gjertsen JE, Espehaug B, Fenstad AM, Lein RK, Ellison P, Hol PJ, Furnes O (2019) Cementing technique for primary knee arthroplasty: a scoping review. Acta Orthop 90:582–589

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

None.

Funding

None.

Author information

Authors and Affiliations

Authors

Contributions

K.I.K. designed and supervised the study. K.I.K. and K.U.M. wrote and edited the manuscript. J.H.K. co-wrote and edited the manuscript. K.I.K. conducted surgical procedures and follow-up evaluations. All the authors reviewed and then approved the manuscript.

Corresponding author

Correspondence to Kyeonguk Min.

Ethics declarations

Ethics approval and consent to participate

This study had been approved from IRB (KHNMC 2023–10-012).

Consent for publication

Agreed.

Competing interests

None.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kim, KI., Kim, JH. & Min, K. Does the clinical and radiologic outcomes following total knee arthroplasty using a new design cobalt-chrome tibial plate or predecessor different?. Knee Surg & Relat Res 36, 34 (2024). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s43019-024-00239-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s43019-024-00239-0

Keywords